SUPER XPRESS VIP – SX
The SUPER XPRESS VIP has a unique pre-plumbed patented design making the installation quick and efficient; with concealed cable routing, integral expansion vessels and all the pipework connections on top of cylinder hidden under a lid.
SX is insulated with award-winning OSO Vacuum Insulation Panel (VIP) technology, ensuring reduced heat loss and energy consumption. In addition, the OSO SX has up to 20% higher hot water capacity than the competition, making it possible to choose a lower volume cylinder thus saving on both cost and energy usage. Downsizing also saves space and improves the already low heat loss figure, helping with SAP/part L compliance.
SX VIP to 210 litres can share a footprint with a washing machine, using additional washing machine frame.
WHY SUPER XPRESS?
20% MORE HOT WATER than other cylinders enabling cylinder to be downsized
Downsizing reduces heat loss figure
Integral expansion vessels
Practically pre-plumbed unit
Labour saving up to 70%
Shortest cylinder system on the market
Unique patented design with a 25 year warranty
Pipes and cables hidden
Fitting template provided
Easy installation
Advantages
S-DESIGN – All connections hidden
NANOPUR – High-grade insulation
ULTRAWELD – Superior corrosion resistance
INCOTEC – High durability in hard water
TARIFF-READY – Twin immersion heaters (single on 120)
Components
Mixing valve – Preset 60°C
Thermostat – Adjustable 40-70°C
immersion – 3kW
P&T safety valve – 10 bar – 90-95°C
Integrated G3 kit including:
Expansion vessel 2 x 6L supplied factory fitted*
Strainer
PRV
Expansion relief
Drain cock
Tundish
*not 300 L .1 vessel on 120L
Specifications | Unit | SX 120 - 3 kW / 1 × 240 V + VIP | SX 150 - 3+3 kW / 1 × 240 V + VIP | SX 180 - 3+3 kW / 1 × 240 V + VIP | SX 210 - 3+3 kW / 1 × 240 V + VIP | SX 250 - 3+3 kW / 1 × 240 V + VIP | SX 300 - 3+3 kW / 1 × 240 V + VIP |
---|---|---|---|---|---|---|---|
Identification | |||||||
Product no. | OSO | 10 802 661 | 10 802 662 | 10 802 663 | 10 802 664 | 10 802 665 | 10 802 666 |
Product series. | SUPER XPRESS | SUPER XPRESS | SUPER XPRESS | SUPER XPRESS | SUPER XPRESS | SUPER XPRESS | |
Product name | SX 120 - 3 kW / 1 × 240 V + VIP | SX 150 - 3+3 kW / 1 × 240 V + VIP | SX 180 - 3+3 kW / 1 × 240 V + VIP | SX 210 - 3+3 kW / 1 × 240 V + VIP | SX 250 - 3+3 kW / 1 × 240 V + VIP | SX 300 - 3+3 kW / 1 × 240 V + VIP | |
Usage | Hot Water | Hot Water | Hot Water | Hot Water | Hot Water | Hot Water | |
Placement | Floor | Floor | Floor | Floor | Floor | Floor | |
Dimensions | |||||||
Diameter — ⌀ | mm | 580 | 580 | 580 | 580 | 580 | 580 |
Height - H | mm | 870 | 1 050 | 1 160 | 1 300 | 1 550 | 1 750 |
Weight | kg | 37 | 42 | 47 | 52 | 59 | 65 |
Packaging | mm | 595x595x895 | 595x595x1 055 | 610x610x1 165 | 595x595x1 305 | 595x595x1 555 | 595x595x1 755 |
Freight Volume | dm |
317 | 373 | 412 | 462 | 551 | 621 |
Technical / ErP information | |||||||
Capacity | Persons | 2,0 | 2,5 | 3,0 | 3,5 | 4,5 | 5,5 |
Capacity 40C | L | 162 | 254 | 304 | 323 | 386 | 463 |
Volume | L | 111 | 143 | 164 | 193 | 242 | 281 |
Thermostat set point | C | 65 | 70 | 70 | 70 | 70 | 70 |
Heat loss - EN 12897 | Watt | 40 | 47 | 51 | 56 | 62 | 68 |
Heat loss / 24 hrs - EN 12897 | kWh/day | 0.96 | 1.13 | 1,23 | 1,34 | 1,48 | 1.63 |
AEC (energy consumption) | kW/year | 2752 | 4453 | 4499 | 4434 | 4507 | 4490 |
Energy efficiency | % | 37.2 | 37.6 | 37.2 | 37.8 | 37.2 | 37.3 |
Tapping profile | 3XS–XXL | L | XL | XL | XL | XL | XL |
Energy rating | A+–F | C | C | C | C | C | C |
Primary Heating Power | kW | N/A | N/A | 3,0 | N/A | N/A | N/A |
Heat-up time ΔT 55°C Coil | Mins | N/A | N/A | N/A | N/A | N/A | N/A |
Heat-up time ΔT 55°C upper element | Mins | N/A | 74 | 101,0 | 135,0 | 132,0 | 132,0 |
Heat-up time ΔT 55°C lower element | Mins | 130,0 | 174,0 | 201,0 | 235,0 | 297 | 347 |
Recovery time ΔT 55°C coil 70% | Mins | N/A | N/A | N/A | N/A | N/A | N/A |
Recovery time ΔT 55°C upper element 70% | Mins | N/A | 52,0 | 71,0 | 95,0 | 92,0 | 92,0 |
Recovery time ΔT 55°C lower element 70% | Mins | 91,0 | 121,0 | 141,0 | 165,0 | 208 | 243 |