ECOLINE COIL – RI

ECOLINE COIL – RI is a standard design, competitively prcied, high performance unvented cylinder. Ecoline is compact and takes up less height in an airing cupboard than any other cylinder, typically 20 – 30cm lower. Ecoline is supplied with full G3 kit, including drain elbow and can interact with a boiler via thermostat or probe thermistor. Ecoline has a dog-leg coil to heat the entire contents of the cylinder and is supplied with a back-up INCOTEC immersion heater.

ECOLINE COIL has low heat losses through use of NANOPUR* insulation. Smooth heating coils restrict the accumulation of limescale and provide fast heat up and recovery time. As with all OSO cylinders, the inner cylinder is has the superior corrosion resistance of ULTRAWELD and is guaranteed for 25 years. With a standard design at an affordable price, Ecoline is perfect as a replacement cylinder.

WHY ECOLINE COIL?
• Reduce heat loss by 300 kWh* / year with NANOPUR*
• Compatible with standard or thermistor controlled boilers
• 25 year warranty on the stainless steel tank
*Compared to 200 L cylinder with EPS insulation

Advantages

NANOPUR – Class leading insulation
ULTRAWELD – Superior corrosion resistance
INCOTEC – High durability in hard water
SMOOTH COIL – Does not encourage limescale build-up

Components

Immersion th.stat – Adjustable 40-70°C – Preset 60°C
Cylinder th. stat – Adjustable 40-70°C – Preset 60°C
T&P relief valve – 10 bar – 90-95°C
G3 kit – Strainer/PRV/exp. relief/drain cock/tundish
Motorized valve – Honeywell V4043H1056C
Expansion vessel – 12-24 L supplied
Appliance feet – Adjustable – Factory fitted

Downloads

OSO Hotwater UK product brochure

Manual Ecoline Coil – RI 120-300 litres

< More boilers >
Specifications Unit RI 120 - 3 kW / 1 × 230 V + HX 0,5 m²RI 150 - 3 kW / 1 × 230 V + HX 0,8 m²RI 180- 3 kW / 1 × 230 V + HX 0,8 m²RI 210 - 3 kW / 1 × 230 V + HX 0,8 m²RI 250 - 3 kW / 1 × 230 V + HX 0,8 m²RI 300 - 3 kW / 1 × 230 V + HX 0,8 m²
Identification
Product no. OSO 1 327 0301 327 0401 327 0501 327 0601 327 0701 327 080
Product series. ECOLINEECOLINEECOLINEECOLINEECOLINEECOLINE
Product name RI 120 - 3 kW / 1 × 230 V + HX 0,5 m²RI 150 - 3 kW / 1 × 230 V + HX 0,8 m²RI 180- 3 kW / 1 × 230 V + HX 0,8 m²RI 210 - 3 kW / 1 × 230 V + HX 0,8 m²RI 250 - 3 kW / 1 × 230 V + HX 0,8 m²RI 300 - 3 kW / 1 × 230 V + HX 0,8 m²
Usage Hot WaterHot WaterHot WaterHot WaterHot WaterHot Water
Placement FloorFloorFloorFloorFloorFloor
Dimensions
Diameter — ⌀ mm 580580580580580580
Height - H mm 7249041 0141 1541 4041 604
Weight kg 323739435056
Packaging mm 595x595x765595x595x945595x595x1 185595x595x1 185595x595x1 435595x595x1 640
Freight Volume dm3 271335420420508581
Technical / ErP information
Capacity Persons 1,52,53,54,55,56,5
Capacity 40C L 160,0223,0253,0307,0391,0468,0
Volume L 108141160186233271
Thermostat set point C 606060606060
Heat loss - EN 12897 Watt 435158627481
Heat loss / 24 hrs - EN 12897 kWh/day 1,031,221,391,491,781,94
AEC (energy consumption) kW/year N / AN / AN / AN / AN / AN / A
Energy efficiency % N/AN/AN/AN/AN/AN/A
Tapping profile 3XS–XXL N / AN / AN / AN / AN / AN / A
Energy rating A+–F BBCCCC
Primary Heating Power kW 13,617,217,317,116,816,5
Heat-up time ΔT 55°C Coil Mins 21,024,029,033,042,049,0
Heat-up time ΔT 55°C upper element Mins N/AN/AN/AN/AN/AN/A
Heat-up time ΔT 55°C lower element Mins N/AN/AN/AN/AN/AN/A
Recovery time ΔT 55°C coil 70% Mins 15,017,020,023,029,035,0
Recovery time ΔT 55°C upper element 70% Mins N/AN/AN/AN/AN/AN/A
Recovery time ΔT 55°C lower element 70% Mins N / AN / AN / AN / AN / AN / A